Basic Info.
Voltage
Low and Medium Voltage Cable
Wire Core Material
Red Copper Wire
Product Description
Product Description
Code | : | BV, H07V-U, NYA |
Standards | : | 227IEC01, BS 6004, VDE0281-3 |
Construction | : | 1- Solid Copper Conductor |
| | 2- PVC insulation |
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, |
| | under ground installation. |
Technical Data | : | Max. operating temperature 70 ºC |
| | Short circuit temperature 160 ºC |
Nominal Cross Section | Wire Diameter | Thickness of insulation | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
mm2 | No. ×mm | mm | min | max | Ù/km | kg/km | Pip A | Air A |
1.5 | 1.35 | 0.7 | 2.6 | 3.2 | 12.1 | 19 | 16 | 24 |
2.5 | 1.73 | 0.8 | 3.2 | 3.9 | 7.41 | 29 | 20 | 32 |
4 | 2.19 | 0.8 | 3.6 | 4.4 | 4.61 | 42 | 26 | 42 |
6 | 2.68 | 0.8 | 4.1 | 5.0 | 3.08 | 62 | 35 | 55 |
10 | 3.50 | 1.0 | 5.3 | 6.4 | 1.83 | 110 | 46 | 75 |
450/750V Code | : | H07V-R, NYA |
Standard | : | IEC 227, BS 6004,VDE 0281 |
Construction | : | 1- Stranded Copper Conductor |
| | 2- PVC Insulation |
Application | : | Preferably for installation indoors. in cable ducts and in industrial plants or |
| | switching stations. under ground installation. |
Technical Data | : | Max. operating temperature 70ºC |
| | Short circuit temperature 160ºC |
Nominal Cross Section | Number of wires and Dia. | Thickness of insulation | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 7×0.51 | 0.7 | 2.7 | 3.3 | 12.1 | 22.0 | 16 | 25 |
2.5 | 7×0.66 | 0.8 | 3.3 | 4.0 | 7.41 | 36.0 | 20 | 34 |
4 | 7×0.83 | 0.8 | 3.8 | 4.6 | 4.61 | 52.0 | 26 | 45 |
6 | 7×1.02 | 0.8 | 4.3 | 5.2 | 3.08 | 74.0 | 35 | 57 |
10 | 7×1.32 | 1.0 | 5.6 | 6.7 | 1.83 | 110 | 46 | 75 |
16 | 7×1.68 | 1.0 | 6.4 | 7.8 | 1.15 | 170 | 62 | 100 |
25 | 7×2.20 | 1.2 | 8.1 | 9.7 | 0.727 | 265 | 82 | 130 |
35 | 7×2.55 | 1.2 | 9.0 | 10.9 | 0.524 | 360 | 100 | 160 |
50 | 7×3.00 | 1.4 | 10.6 | 12.8 | 0.387 | 501 | 120 | 200 |
H07V-K
450/750V Code | : | RV,H07V-K, NYAF |
Standard | : | IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC Insulation |
Application | : | For protected installation in equipment and lighting fitting. |
| | Also for in conduit, on and under plaster |
Technical Data | : | Max. operating temperature 70ºC |
| | Short circuit temperature 160ºC |
Nominal Cross Section | Number of wires and Dia. | Thickness of insulation | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 27×0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45×0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50×0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75×0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73×0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119×0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182×0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252×0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364×0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 120 | 198 |
H05VV-F
300/500V Code | : | H05VV-F, RVV |
Standard | : | IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC insulation. 3- PVC Filling. 4- PVC Outer Sheath |
Application | : | For household appliances under medium mechanical stress-also in damp and wet areas |
Technical Data | : | Max. operating temperature 70ºC |
| | Short circuit temperature 160ºC |
Nominal Cross Section | Number and Dia. | Thickness of insulation | Thickness of Sheath | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
No | No. ×mm | mm | Mm | min | max | Ù/km | Kg/km | Air A |
2×0.75 | 22×0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.1 | 8 |
2×1 | 30×0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.0 | 12 |
2×1.5 | 27×0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2×2.5 | 45×0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2×4 | 50×0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2×6 | 75×0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2×10 | 73×0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3×0.75 | 22×0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3×1 | 30×0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.1 | 12 |
3×1.5 | 27×0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3×2.5 | 45×0.25 | 0.8 | 1.0 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3×4 | 50×0.30 | 0.8 | 1.1 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3×6 | 75×0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3×10 | 73×0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4×0.75 | 22×0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.2 | 8 |
4×1 | 30×0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4×1.5 | 27×0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4×2.5 | 45×0.25 | 0.8 | 1.1 | 11.0 | 12.5 | 7.98 | 213 | 26 |
4×4 | 50×0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4×6 | 75×0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4×10 | 73×0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4×16 | 119×0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5×0.75 | 22×0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5×1 | 30×0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5×1.5 | 27×0.25 | 0.7 | 1.1 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5×2.5 | 45×0.25 | 0.8 | 1.2 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5×4 | 50×0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5×6 | 75×0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5×10 | 73×0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
5×16 | 119×0.40 | 0.9 | 1.6 | 22.3 | 23.2 | 1.21 | 1170 | 80 |
H05VVH2-F
300/500V Code | : | H05VVH2-F |
Standard | : | TS 9760, IEC 227, VDE 0281,BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC insulation |
| | 3- PVC outer sheath |
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical stresses. |
| | It is used for hand tools and house hold appliances with flat shape. |
Technical Data | : | Max. operating temperature 70ºC |
| | Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section | Number and Dia. | Thickness of insulation | Approx. OD | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
No×mm2 | No. ×mm | min | max | max.mm | Ù/km | Kg/km | Pip A | Air A |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 6.40 | 26.0 | 37.0 | - | 13 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 6.60 | 19.5 | 61.1 | 12 | 16 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 4.60 × 7.60 | 13.3 | 85.0 | 16 | 20 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 5.70 × 9.40 | 7.98 | 128 | 21 | 27 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 6.40 × 10.6 | 4.95 | 185 | 27 | 36 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 8.80 | 26.0 | 65.0 | - | 13 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 9.10 | 19.5 | 77.0 | 12 | 16 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 4.70 × 10.50 | 13.3 | 104 | 16 | 20 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 5.90 × 13.30 | 7.98 | 159 | 21 | 27 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 6.60 × 15.60 | 4.95 | 228 | 27 | 36 |
H05V2-K
300/500V Code | : | H05V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC insulation |
Application | : | For protected installation in equipment and lighting fitting. |
| | Also for in conduit. on and under plaster. |
Technical Data | : | Max. operating temperature 90 ºC |
| | Short circuit temperature 160 ºC |
Nominal Cross Section | Number and Dia. | Thickness of insulation | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
0.5 | 15 × 0.20 | 0.6 | 2.1 | 2.5 | 39.0 | 10.0 | - | - |
0.75 | 22 × 0.20 | 0.6 | 2.2 | 2.7 | 26.0 | 12.0 | - | 16 |
1 | 30 × 0.20 | 0.6 | 2.4 | 2.8 | 19.5 | 15.0 | 12 | 20 |
H07V2-K
450/750V
Code | : | H07V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC insulation |
Application | : | For protected installation in equipment and lighting fitting. |
| | Also for in conduit. on and under plaster. |
Technical Data | : | Max. operating temperature 90 ºC |
| | Short circuit temperature 160 ºC |
Nominal Cross Section | Number and Dia. | Thickness of insulation | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 27 × 0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45 × 0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50 × 0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75 × 0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73 × 0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119 × 0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182 × 0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252 × 0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364 × 0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 132 | 198 |
H05V2V2-F
300/500V Code | : | H05V2V2-F |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
| | 2- PVC insulation |
| | 3- PVC outer sheath |
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical |
| | stresses. It is used for hand tools. heat tools and house hold appliances with flat shape. |
Technical Data | : | Max. operating temperature 90ºC |
| | Short circuit temperature 160 ºC |
Num. of Cores and Nominal Cross Section | Number and Dia. | Thickness of insulation | Thickness of Sheath | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
|
|
|
|
No ×mm2 | mm | mm | | min | max | Ù/km | Kg/km | Air A |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.0 | 8 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.1 | 12 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2 × 6 | 75 × 0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2 × 10 | 73 × 0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.0 | 12 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3 × 6 | 75 × 0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3 × 10 | 73 × 0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.0 | 8 |
4 × 1 | 30 × 0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11 | 12.5 | 7.98 | 213 | 26 |
4 × 4 | 50 × 0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4 × 6 | 75 × 0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4 × 10 | 73 × 0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4 × 16 | 119 × 0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5 × 1 | 30 × 0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5 × 1.5 | 27 × 0.25 | 0.7 | 1.0 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5 × 4 | 50 × 0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5 × 6 | 75 × 0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5 × 10 | 73 × 0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
NVV
300/500V Code | : | NVV |
Standard | : | TS 9759 HD 21,4 S2, VDE 0250-204, BS 6004 |
Construction | : | 1- Solid or Stranded Copper Conductor |
| | 2- PVC insulation 3- PVC Filling 4- PVC outer sheath |
Application | : | Fixed wiring in dry and damp premises, in conduits. on or under plaster and on |
| | insulators over plaster, switching. |
Technical Data | : | Max. operating temperature 70ºC Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section | Number and Dia. | Thickness of insulation | Thickness of Sheath | Mean overall diameter | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
No ×mm2 | mm | mm | mm | min | max | Ù/km | Kg/km | Air A |
2 × 1.5 | 1.35 | 0.7 | 1.2 | 8.4 | 10.0 | 12.1 | 108 | 22 |
2 × 2.5 | 1.73 | 0.8 | 1.2 | 9.6 | 11.5 | 7.41 | 148 | 30 |
2 × 4 | 2.19 | 0.8 | 1.2 | 10.5 | 12.5 | 4.61 | 194 | 40 |
2 × 6 | 2.68 | 0.8 | 1.2 | 11.5 | 13.5 | 3.08 | 250 | 51 |
2 × 10 | 7 × 1.32 | 1.0 | 1.4 | 14.5 | 16.5 | 1.83 | 427 | 70 |
2 × 16 | 7 × 1.66 | 1.0 | 1.4 | 16.5 | 20.0 | 1.15 | 604 | 94 |
3 × 1.5 | 1.35 | 0.7 | 1.2 | 8.8 | 10.5 | 12.1 | 128 | 22 |
3 × 2.5 | 1.73 | 0.8 | 1.2 | 10.0 | 12.0 | 7.41 | 179 | 30 |
3 × 4 | 2.19 | 0.8 | 1.2 | 11.0 | 13.0 | 4.61 | 239 | 40 |
3 × 6 | 2.68 | 0.8 | 1.2 | 12.5 | 14.5 | 3.08 | 319 | 51 |
3 × 10 | 7 × 1.32 | 1.0 | 1.4 | 15.5 | 17.5 | 1.83 | 535 | 70 |
3 × 16 | 7 × 1.66 | 1.0 | 1.4 | 18.0 | 21.5 | 1.15 | 769 | 94 |
4 × 1.5 | 1.35 | 0.7 | 1.2 | 9.6 | 11.5 | 12.1 | 154 | 18.5 |
4 × 2.5 | 1.73 | 0.8 | 1.2 | 11.0 | 13.0 | 7.41 | 219 | 25 |
4 × 4 | 2.19 | 0.8 | 1.2 | 12.0 | 14.5 | 4.61 | 301 | 34 |
4 × 6 | 2.68 | 0.8 | 1.2 | 14.0 | 16.0 | 3.08 | 399 | 43 |
4 × 10 | 7 × 1.32 | 1.0 | 1.4 | 16.5 | 19.0 | 1.83 | 669 | 60 |
4 × 16 | 7 × 1.66 | 1.0 | 1.4 | 20.0 | 23.5 | 1.15 | 970 | 80 |
5 × 1.5 | 1.35 | 0.7 | 1.2 | 10.0 | 12.0 | 12.1 | 181 | 15.5 |
5 × 2.5 | 1.73 | 0.8 | 1.2 | 12.0 | 14.5 | 7.41 | 262 | 22 |
5 × 4 | 2.19 | 0.8 | 1.2 | 13.5 | 16.0 | 4.61 | 364 | 31 |
5 × 6 | 2.68 | 0.8 | 1.2 | 15.0 | 17.5 | 3.08 | 483 | 40 |
5 × 10 | 7 × 1.32 | 1.0 | 1.4 | 18.0 | 21.0 | 1.83 | 828 | 56.5 |
FLAT CABLES
300/500V Code | : | Flat Cables |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Solid Copper Conductor |
| | 2- PVC insulation |
| | 3- PVC outer sheath |
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching |
| | stations, under ground installation, with additional protection where mechanical damage |
| | is unexpected. |
Technical Data | : | Max. operating temperature 70ºC |
| | Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section | Number and Dia. | Thickness of insulation | Thickness of Sheath | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
No. ×mm2 | No. ×mm | mm | mm | Ù/km | Kg/km | Pipe A | Air A |
2 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 50.0 | - | 19 |
2 × 1.5 | 1.35 | 0.7 | 0.8 | 12.1 | 66.0 | 32 | 20 |
2 × 2.5 | 1.73 | 0.8 | 1.0 | 7.41 | 104 | 42 | 20 |
2 × 4 | 2.19 | 0.8 | 1.1 | 4.61 | 143 | 54 | 20 |
3 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 73.0 | - | 20 |
3 × 1.5 | 1.35 | 0.7 | 0.9 | 12.1 | 101 | 26 | 20 |
3 × 2.5 | 1.73 | 0.8 | 1.1 | 7.41 | 158 | 34 | 20 |
3 × 4 | 2.19 | 0.8 | 1.2 | 4.61 | 216 | 44 | 20 |
FLAT TWIN&THREE CORE300/500V Code | : | FLAT TWIN& THREE CORE CABLES |
Standard | : | BS6004 |
Construction | : | 1- Stranded Copper Conductor |
| | 2- PVC insulation |
| | 3- PVC outer sheath |
Application | : | These Cables are used in dry or damp locations for fixed installation. |
| | Suitable for installation in walls or embedded in plaster. |
Technical Data | : | Max. operating temperature 70ºC |
Num. of Cores and Nominal Cross Section | Number and Dia. | Thickness of insulation | Thickness of Sheath | Conductor DC resistance at 20ºC | Approx. Total Weight | Max. Current Carrying Capacity at 30ºC |
No ×mm2 | No. ×mm | mm | mm | Ù/km | Kg/km | Pipe A | Air A |
2 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 76..0 | 32 | 20 |
2 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 110 | 42 | 27 |
2 × 4 | 7 × 0.83 | 0.8 | 1.0 | 4.61 | 148 | 54 | 37 |
3 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 102 | 26 | 18 |
3 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 152 | 34 | 25 |
3 × 4 | 7 × 0.83 | 0.8 | 1.1 | 4.61 | 224 | 44 | 34 |
Address:
Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Company Introduction:
Different kinds of products are available in our company. We′re pleased to get your Inquiry and we will reply you as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.